Question 1 |
All of the following values are needed to select a heat pump except _____ load.
A | sensible cooling |
B | sensible heating |
C | latent cooling |
D | latent heating |
Question 2 |
All of the following are generally factors in calculating commercial heating and cooling loads except
_____.
A | extensive use of steel and/or glass facades |
B | estimating instructions in ACCA Manual J |
C | large, open areas |
D | significant variations in people load |
Question 3 |
Of the following load factors, _____ has more effect on the cooling load.
A | shaded glass |
B | duct gain/loss |
C | infiltration |
D | wood and metal doors |
Question 4 |
The trap in the condensate drain _____.
A | prevents water from being held in the drain pan by the blower |
B | keeps condensate from freezing |
C | stores condensate in case the drain line is plugged |
D | prevents oil from returning to the evaporator |
Question 5 |
The transfer of heat energy from particle to particle in a substance is known as _____.
A | radiation |
B | convection |
C | conduction |
D | conductance |
Question 6 |
Which of the following is an incorrect statement with regard to refrigerant piping?
A | When the indoor coil and outdoor unit are at the same level, the suction line should be
pitched toward the indoor coil. |
B | When the indoor coil is below the outdoor unit, there should be an oil trap in the suction line
near the indoor unit. |
C | The suction line should always be insulated. |
D | The liquid line should be insulated in areas where it is exposed to direct sunlight. |
Question 7 |
Which form of heat transfer can travel through a vacuum?
A | Radiation |
B | Convection |
C | Conduction |
D | Conductance |
Question 8 |
The hot gas line conveys _____.
A | hot, high-pressure liquid refrigerant |
B | low-pressure liquid refrigerant |
C | low-temperature, low-pressure vapor |
D | hot, high-pressure vapor |
Question 9 |
Of the following load factors, _____ has more effect on heating load than it does on cooling load.
A | people load |
B | infiltration |
C | window glass |
D | roof color |
Question 10 |
The insulated duct that has the lowest pressure loss is _____.
A | metal duct with inside insulation |
B | metal duct with outside insulation |
C | fiberglass duct |
D | flexible duct |
Question 11 |
In order to determine the heat gain of a southern exposure 6' by 20' double-pane window with a
heat transfer multiplier of 38, you should _____.
A | look up the heat gain in a table |
B | determine the R-value, then use a table to find the heat gain |
C | divide the area of the window by the HTM |
D | multiply the area of the window by the HTM |
Question 12 |
The total equivalent length of a supply and/or return duct run is the sum of the _____.
A | measured vertical straight lengths of duct in the path plus the equivalent lengths of all fittings
in the path |
B | measured horizontal and vertical straight lengths of duct in the path plus the equivalent
lengths of all fittings in the path |
C | measured horizontal straight lengths of duct in the path plus the equivalent lengths of all
fittings in the path |
D | equivalent lengths of all fittings and transitions in the path plus the grille losses |
Question 13 |
Sliding glass doors are treated as _____.
A | windows |
B | partially shaded window |
C | walls |
D | doors |
Question 14 |
A room requiring an airflow of 270 cfm is supplied by three outlets. The air delivered by each
outlet should be about _____ cfm.
A | 300 |
B | 810 |
C | 90 |
D | 270 |
Question 15 |
When calculating the heating load of basement walls, how are the portions above and below grade
treated?
A | If most of the wall is below grade, the entire wall is treated as below grade, and vice versa. |
B | If the wall is insulated, it has no heating load. |
C | The load of the portion above grade is calculated separately from that of the portion below
grade. |
D | They are treated the same. |
Question 16 |
Air systems with high sidewall or ceiling air outlets normally are designed to favor _____.
A | heating over cooling |
B | cooling only |
C | heating only |
D | cooling over heating |
Question 17 |
The air conditioning function that is most affected by duct losses is _____.
A | cooling |
B | heating and cooling are equally affected |
C | heating |
D | humidification |
Question 18 |
The external static pressure of the air distribution system includes all of the following except _____.
A | component losses not included in the fan rating |
B | fan assembly losses |
C | return duct system losses |
D | supply duct system losses |
Question 19 |
Latent heat is created by all of the following except _____.
A | people |
B | appliances |
C | direct sunlight |
D | infiltration |
Question 20 |
Each fitting and transition used in a duct system has _____.
A | a gain coefficient value (C-value) |
B | approximately the same friction loss |
C | a friction loss equal to a predetermined length of the same size straight duct |
D | less friction loss per foot as the same size straight duct |
Question 21 |
In selecting a heating or cooling system, _____ percent undersizing is generally acceptable.
A | 5 |
B | 10 |
C | 20 |
D | 15 |
Question 22 |
Velocity pressure in a duct equals the _____.
A | static pressure minus total pressure |
B | total pressure minus the velocity pressure |
C | static pressure plus velocity pressure |
D | total pressure minus the static pressure |
Question 23 |
Oversizing cooling equipment can result in _____.
A | inadequate cooling on design days |
B | poor humidity control |
C | improved operating efficiency |
D | excessive cooling on design days |
Question 24 |
Within an air distribution system, the lowest pressure level is found at the _____.
A | output of the blower |
B | input to the blower |
C | conditioned space |
D | input to the return duct |
Question 25 |
The practice of using a cooling coil with higher capacity than the condensing coil (mix-matching) is
used in areas with ________.
A | low humidity and high dry-bulb temperatures |
B | high humidity |
C | low humidity and low dry-bulb temperatures |
D | low humidity |
Once you are finished, click the button below. Any items you have not completed will be marked incorrect.
Get Results
There are 25 questions to complete.
← |
List |
→ |
Return
Shaded items are complete.
1 | 2 | 3 | 4 | 5 |
6 | 7 | 8 | 9 | 10 |
11 | 12 | 13 | 14 | 15 |
16 | 17 | 18 | 19 | 20 |
21 | 22 | 23 | 24 | 25 |
End |
Return
You have completed
questions
question
Your score is
Correct
Wrong
Partial-Credit
You have not finished your quiz. If you leave this page, your progress will be lost.
Correct Answer
You Selected
Not Attempted
Final Score on Quiz
Attempted Questions Correct
Attempted Questions Wrong
Questions Not Attempted
Total Questions on Quiz
Question Details
Results
Date
Score
Hint
Time allowed
minutes
seconds
Time used
Answer Choice(s) Selected
Question Text
All done
Need more practice!
Keep trying!
Not bad!
Good work!
Perfect!