Energy Conservation Equipment
Energy Conservation Equipment
Start
Congratulations - you have completed Energy Conservation Equipment.
You scored %%SCORE%% out of %%TOTAL%%.
Your performance has been rated as %%RATING%%
Your answers are highlighted below.
Question 1 |
A fixed-plate air-to-air heat exchanger used in an ERV unit _____.
A | transfers sensible heat only |
B | transfers latent heat only |
C | precools ventilation air in the winter |
D | precools ventilation air in the summer |
Question 2 |
A rotary air-to-air heat exchanger that has a(n) _____ wheel media can recover total heat.
A | aluminum |
B | Monel® |
C | lithium chloride |
D | copper |
Question 3 |
A refrigeration system in which the hot discharge gas from the reciprocating compressor can be
diverted from the system condenser and into a heat recovery condenser is commonly called a
_____.
A | double-bundle condenser system |
B | dual-condenser system |
C | bypass condenser system |
D | heat pump heat reclaim system |
Question 4 |
In a chiller system with a double-bundle condenser, the compressor hot discharge gas can be
routed to _____.
A | the cooling condenser |
B | the heat recovery condenser |
C | neither the heat recovery condenser or the cooling condenser |
D | both the heat recovery condenser and the cooling condenser |
Question 5 |
The coils in a runaround loop system are installed in the exhaust duct and supply duct. Installation
of the coils in these locations gives _____.
A | no temperature difference between the airstreams flowing in the ducts |
B | the minimum temperature difference between the airstreams flowing in the ducts |
C | the greatest temperature difference between the airstreams flowing in the ducts |
D | a recovery efficiency exceeding 80 percent |
Question 6 |
A heat pipe heat exchanger _____.
A | decreases the dehumidification capacity of a system |
B | transfers heat from one end of the exchanger to the other |
C | is an active device that needs no electrical energy input |
D | operates constantly, regardless of the temperature difference between the airstreams flowing
in the supply and exhaust ducts |
Question 7 |
Thermosiphon loops are used when __________.
A | heat exchangers may be enclosed in a single shell |
B | the supply and exhaust air ducts are not mounted next to each other |
C | the supply and exhaust air ducts must be mounted next to each other |
D | gravity cannot be used to transfer energy between two airstreams |
Question 8 |
In an air-side economizer, the changeover from the mechanical cooling mode to the free cooling
mode is controlled mainly by the _____.
A | outdoor air enthalpy sensor |
B | return air enthalpy sensor |
C | space thermostat |
D | discharge air sensor |
Question 9 |
In a steam system that uses a heat recovery flash tank _____ the flash tank.
A | high-pressure steam and high-pressure condensate can be piped out of |
B | high-or medium-pressure steam condensate can be piped into |
C | hot water can be piped into and low-pressure steam piped out of |
D | low-pressure steam and high-pressure condensate are piped out of |
Question 10 |
Which of the following statements most accurately describes a utility demand reduction program?
A | Comfort cooling systems are only permitted to operate at night during the summer. |
B | The utility charges twice as much for energy during peak demand hours. |
C | Office buildings are required to close during peak demand hours. |
D | Some comfort air conditioning equipment is turned off during peak demand hours. |
Question 11 |
The three types of airflow in a fixed-plate heat exchanger are _____.
A | counterflow, direct flow, crossflow |
B | vertical flow, parallel flow, counterflow |
C | crossflow, direct flow, reverse flow |
D | parallel flow, crossflow, counterflow |
Question 12 |
The purpose of a heat pipe heat exchanger is to _____.
A | extract sensible heat from the exhaust air |
B | preheat the air entering the evaporator |
C | remove latent heat from the indoor air |
D | provide emergency heat in the event of a compressor failure |
Question 13 |
During the charge cycle of an IceBank® system, _____.
A | the ice banks alone are used to satisfy the cooling demand |
B | the chiller capacity is used to make ice |
C | the ice bank is used to augment the chiller |
D | any leftover ice is melted so the freezing process can start again |
Question 14 |
The purpose of a condenser heat recovery system is to _____.
A | store heat for later use |
B | capture heat that is rejected by the condenser |
C | extract heat from the refrigerant before it enters the condenser |
D | pre-cool air entering the evaporator |
Once you are finished, click the button below. Any items you have not completed will be marked incorrect.
Get Results
There are 14 questions to complete.
← |
List |
→ |
Return
Shaded items are complete.
1 | 2 | 3 | 4 | 5 |
6 | 7 | 8 | 9 | 10 |
11 | 12 | 13 | 14 | End |
Return
You have completed
questions
question
Your score is
Correct
Wrong
Partial-Credit
You have not finished your quiz. If you leave this page, your progress will be lost.
Correct Answer
You Selected
Not Attempted
Final Score on Quiz
Attempted Questions Correct
Attempted Questions Wrong
Questions Not Attempted
Total Questions on Quiz
Question Details
Results
Date
Score
Hint
Time allowed
minutes
seconds
Time used
Answer Choice(s) Selected
Question Text
All done
Need more practice!
Keep trying!
Not bad!
Good work!
Perfect!