Question 1 |
When testing an electrical system that is inoperable, what is commonly the first test that is performed?
A | Amperage test |
B | Resistance test |
C | Voltage test |
D | Wattage test |
Question 2 |
When a contactor coil is energized, what type of reading should be obtained across a normally closed set of contacts that is in an operating circuit?
A | 0 volts |
B | Source voltage |
C | 0 ohms |
D | Source amperage |
Question 3 |
If source voltage is applied to a load and the load is inoperable, what can be said about the load?
A | It has a short circuit |
B | It has a defective control circuit |
C | It has a grounded circuit |
D | It has a open circuit |
Question 4 |
If a measurable voltage reading is obtained when testing across a normally open set of contacts of a relay that is energized, what is the problem with the relay?
A | There is no problem |
B | The contacts are burnt |
C | The contacts are closed |
D | The contacts are shorted |
Question 5 |
When troubleshooting a circuit using an ohmmeter,
A | Power must be supplied to the circuit |
B | The meter must always be set to the R X 1 scale |
C | The component being tested must be removed from the circuit |
D | The circuit being tested must have current flow |
Question 6 |
If a measurable resistance if obtained when testing across a normally closed set of contacts on a relay when using an ohmmeter, what is the problem with the relay?
A | There is no problem |
B | The contacts are burnt |
C | The contacts are open |
D | The contacts are shorted |
Question 7 |
When measuring the resistance of a load
A | Start by setting the ohmmeter to the R X !00,000 scale |
B | Start by setting the ohmmeter to the R X 10,000 scale |
C | Start by setting the ohmmeter to the R X 1,000 scale |
D | Start by setting the ohmmeter to the R X 1 scale |
Question 8 |
When measuring the resistance of a load, what reading should be obtained if the load is operable?
A | Infinite resistance |
B | Measureable resistance |
C | Zero resistance |
D | No continuity |
Question 9 |
Which of the following resistance readings best explains the meaning of continuity?
A | An infinite and zero resistance reading |
B | An measurable and infinite resistance reading |
C | An measurable and zero resistance reading |
D | An infinite resistance reading |
Question 10 |
When measuring the resistance of a shorted electrical load, what reading will be obtained?
A | Infinite resistance |
B | Zero or very low measurable resistance |
C | 0 ohm only |
D | High measurable resistance |
Question 11 |
When measuring the resistance of an electrical load that has burnt open, what reading will be obtained?
A | Infinite resistance |
B | Zero or very low measureable resistance |
C | 0 ohm only |
D | High measurable resistance |
Question 12 |
When measuring the resistance of an electrical load that has shorted to ground, it should be tested with?
A | R X 1 scale |
B | R X 10 scale |
C | . R X 1,000 scale |
D | R X 100,000 scale |
Question 13 |
When troubleshooting a circuit using a clamp on ammeter,
A | The circuit must be de energized, and the meter must be clamped around two wires |
B | The circuit must be energized, and the meter must be clamped around two wires |
C | The circuit must be energized, and the meter must be clamped around one wire |
D | The circuit must be de energized, and the meter must be clamped around two wires |
Question 14 |
When measuring a 24 volt circuit using an ammeter what must be used to increase the amperage to a measurable level?
A | A current multiplier |
B | A voltage rectifier |
C | A step up transformer |
D | A potentiometer |
Question 15 |
What reading would be obtained when measuring the amperage of a short circuit?
A | 0 amps |
B | Steady measurable amperage |
C | Excessive amperage |
D | Low amperage |
Question 16 |
What reading would be obtained when measuring the amperage of an open circuit?
A | 0 amps |
B | Steady measurable amperage |
C | Excessive amperage |
D | Low amperage |
Question 17 |
Refer to the attached figure. The system depicted by the diagram is a _____ system.
SCHEMATIC
A | electric heat, electric cooling |
B | gas heat, electric cooling |
C | cooling only |
D | heat pump |
Once you are finished, click the button below. Any items you have not completed will be marked incorrect.
Get Results
There are 17 questions to complete.
← |
List |
→ |
Return
Shaded items are complete.
1 | 2 | 3 | 4 | 5 |
6 | 7 | 8 | 9 | 10 |
11 | 12 | 13 | 14 | 15 |
16 | 17 | End |
Return
You have completed
questions
question
Your score is
Correct
Wrong
Partial-Credit
You have not finished your quiz. If you leave this page, your progress will be lost.
Correct Answer
You Selected
Not Attempted
Final Score on Quiz
Attempted Questions Correct
Attempted Questions Wrong
Questions Not Attempted
Total Questions on Quiz
Question Details
Results
Date
Score
Hint
Time allowed
minutes
seconds
Time used
Answer Choice(s) Selected
Question Text
All done
Need more practice!
Keep trying!
Not bad!
Good work!
Perfect!