Question 1 |
A hot-water boiler capable of working at water temperatures above 250°F would be classified as a
_____ boiler.
A | low-pressure |
B | medium- or high-pressure |
C | copper-finned tube |
D | cast-iron |
Question 2 |
A steel boiler design in which the flue gases are contained inside the tubes and the heated water is
circulated outside the tubes is called a _____ boiler.
A | cast-iron |
B | steel watertube |
C | copper-finned tube |
D | steel firetube |
Question 3 |
Electric boilers control heating capacity by _____.
A | reducing the water flow rate |
B | controlling how much of the heating element is immersed in the water |
C | varying the voltage to the heating elements |
D | activating or deactivating individual heating elements |
Question 4 |
Water flow switches are generally used on a(n) _____ boiler.
A | electric |
B | copper-finned tube |
C | cast-iron |
D | steel firetube |
Question 5 |
When an air elimination strategy is used for hydronic system air management, a _____ is used to
seperate the air cushion from the water.
A | purge reservoir |
B | commercial air separator |
C | bladder-type expansion tank |
D | compression tank |
Question 6 |
Centrifugal pumps are typically used for applications _____.
A | containing thick and heavy fluids |
B | that require large pressure differentials |
C | that do not require extreme pressure differentials |
D | other than commercial hydronic systems |
Question 7 |
A multistage centrifugal pump contains one or more _____.
A | discharge fittings |
B | pump drive shafts |
C | drive motors |
D | impellers |
Question 8 |
A valve commonly installed on the discharge side of a hydronic pump in a large system is the
_____ valve.
A | multi-purpose |
B | butterfly |
C | gate |
D | flow meter |
Question 9 |
Three-way valves are typically employed for _____.
A | mixing and draining |
B | mixing and diverting |
C | mixing and flow balancing |
D | diverting and flow balancing |
Question 10 |
The condenser in a chiller unit cools the _____.
A | water circulating through the cooling tower |
B | chilled water as it circulates through the building |
C | chiller system refrigerant |
D | system secondary coolant so that it condenses into a liquid |
Question 11 |
One style of chiller that is available in capacities as low as 5 tons is the _____ chiller.
A | absorption |
B | non-mechanical |
C | reciprocating |
D | centrifugal |
Question 12 |
A device used to remove unwanted air from the refrigerant circuit of a low-pressure chiller is the
_____.
A | air separator |
B | purge unit |
C | expansion tank |
D | air vent |
Question 13 |
In an induced-draft cooling tower, air _____.
A | is pushed through the tower horizontally |
B | is pushed through the tower by a fan |
C | circulates through the tower by natural thermal air currents |
D | is drawn through the tower by a fan |
Question 14 |
An air handling unit generally produces airflows in excess of _____ cfm.
A | 1,000 |
B | 500 |
C | 2,000 |
D | 100 |
Question 15 |
In a two-pipe, dual temperature hydronic system, changeover from the heating mode to the
cooling mode cannot occur until _____.
A | the boiler is sufficiently heated |
B | cooling is needed in every area of the building |
C | the outdoor temperatures are above 70°F |
D | the water temperature in the piping is cool enough to prevent over-pressurization or
overloading of the chiller |
Question 16 |
In a primary-secondary loop system, the transfer of water between the two loops occurs _____.
A | in the common pipe |
B | in the primary loop |
C | at the primary pump inlet |
D | in the secondary loop |
Question 17 |
In a primary-secondary loop chilled water system, each primary pump is sized to _____.
A | accommodate the flow requirements of the water-cooled condenser |
B | handle the flow through all connected chillers simultaneously |
C | handle only the head and flow rate of its related chiller |
D | also provide flow through the secondary loop at low cooling loads |
Question 18 |
Before attempting to balance a water system, you should _____.
A | ensure that none of the mechanical systems have been turned on yet |
B | ensure that the boiler and/or chiller have been started up per the manufacturer's instructions |
C | always ensure that air balancing has first been completed |
D | not allow circulating pumps to operate until the balancing procedure is completed |
Question 19 |
At the highest point in a piping system, static pressure is _____.
A | 0.433 psi |
B | at its maximum |
C | 0 psi |
D | 1 psi |
Question 20 |
One Bohp equals _____ watts.
A | 9.8 |
B | 200 |
C | 22.5 |
D | 433 |
Once you are finished, click the button below. Any items you have not completed will be marked incorrect.
Get Results
There are 20 questions to complete.
← |
List |
→ |
Return
Shaded items are complete.
1 | 2 | 3 | 4 | 5 |
6 | 7 | 8 | 9 | 10 |
11 | 12 | 13 | 14 | 15 |
16 | 17 | 18 | 19 | 20 |
End |
Return
You have completed
questions
question
Your score is
Correct
Wrong
Partial-Credit
You have not finished your quiz. If you leave this page, your progress will be lost.
Correct Answer
You Selected
Not Attempted
Final Score on Quiz
Attempted Questions Correct
Attempted Questions Wrong
Questions Not Attempted
Total Questions on Quiz
Question Details
Results
Date
Score
Hint
Time allowed
minutes
seconds
Time used
Answer Choice(s) Selected
Question Text
All done
Need more practice!
Keep trying!
Not bad!
Good work!
Perfect!