Alternative Heating and Cooling Systems
Alternative Heating and Cooling Systems
Start
Congratulations - you have completed Alternative Heating and Cooling Systems.
You scored %%SCORE%% out of %%TOTAL%%.
Your performance has been rated as %%RATING%%
Your answers are highlighted below.
Question 1 |
Unless they have a catalytic element, wood stove smoke emissions cannot exceed _____ grams per
hour.
A | 0.4 |
B | 7.5 |
C | 4.1 |
D | 10 |
Question 2 |
Which of the following are found in an evaporative cooler?
A | Compressor, water pump, water-absorbing pad |
B | Blower assembly, water-absorbing pad, water pump |
C | Water pump, compressor, blower assembly |
D | Water-absorbing pad, compressor, blower assembly |
Question 3 |
A wood-burning stove must be installed at least _____ from a combustible wall.
A | 12" |
B | 24" |
C | 36" |
D | 18" |
Question 4 |
Evaporative pre-coolers save energy by _____.
A | pre-cooling suction gas |
B | evaporating refrigerant |
C | recovering waste heat |
D | lowering head pressure |
Question 5 |
Chilled-beam cooling systems are not widely used in the United States because _____.
A | they are difficult to maintain |
B | they are inefficient |
C | they are noisy |
D | contractors are not familiar with them |
Question 6 |
The U.S. government agency that is responsible for establishing rules governing the burning of
waste oil is the _____.
A | DHS |
B | DOE |
C | EPA |
D | DOD |
Question 7 |
In-floor radiant hydronic heating systems typically use _____ to carry the heated fluid to the
different zones.
A | galvanized steel pipes |
B | rubber tubing |
C | PEX tubing |
D | PVC plastic pipe |
Question 8 |
The fluid circulated through the ground loop of a geothermal heat pump must _____.
A | be non-toxic |
B | contain ethylene-glycol |
C | be non-flammable |
D | be oil-soluble |
Question 9 |
When wood is burned in a wood stove, it can deposit _____ in the chimney or vent.
A | minerals |
B | ash |
C | acid |
D | creosote |
Question 10 |
An 8" diameter stovepipe must be at least _____ away from combustibles.
A | 16" |
B | 12" |
C | 18" |
D | 24" |
Question 11 |
An evaporative pre-cooler is likely to be used if the _____.
A | air conditioner is installed above 5,000' |
B | air conditioner is installed in a hot, humid climate |
C | evaporator is exposed to high ambient temperatures |
D | air conditioner is installed in a desert city |
Question 12 |
The heater used in a waste-oil burner is there to _____.
A | remove contaminants from the waste oil |
B | ignite the oil |
C | comply with DOE waste-oil burning regulations |
D | help maintain oil viscosity |
Question 13 |
Which of the following problems is likely to occur if lake water is brought directly into the
refrigerant-to-water heat exchanger used in a water-source heat pump?
A | Heat output will fluctuate over a wide range. |
B | The heat exchanger may become clogged. |
C | The condenser coil will freeze. |
D | The TXV will hunt. |
Question 14 |
In a passive chilled-beam cooling system, the water supplied to the chilled beam must be _____ the
dew point of the air in the conditioned space.
A | the same temperature as |
B | of a higher viscosity than |
C | warmer than |
D | cooler than |
Question 15 |
A valance cooling system includes a _____.
A | zone valve, blower assembly, and condensate pan |
B | condensate pan, blower assembly, and circulating pump |
C | zone valve, condensate pan, and circulating pump |
D | circulating pump, blower assembly, and zone valve |
Question 16 |
In the U.S., a passive solar heating system requires _____ to be effective.
A | a pump |
B | high-density insulation |
C | south-facing windows |
D | single-pane windows |
Question 17 |
The ground loop in a geothermal heat pump is usually buried about _____ deep.
A | 9' |
B | 3' |
C | 5' |
D | 12' |
Question 18 |
A coal-burning stove can be safely vented using a _____ vent.
A | Type HT |
B | Type C |
C | Type PL |
D | Type B |
Question 19 |
A thermosyphon system is a type of _____ heating system.
A | geothermal |
B | solar |
C | heat pump |
D | valance |
Question 20 |
In heat pump water heaters used to heat potable water, the refrigerant-to-water heat exchanger
must be _____.
A | double-walled |
B | made of aluminum |
C | made of galvanized steel |
D | outside the water tank |
Once you are finished, click the button below. Any items you have not completed will be marked incorrect.
Get Results
There are 20 questions to complete.
← |
List |
→ |
Return
Shaded items are complete.
1 | 2 | 3 | 4 | 5 |
6 | 7 | 8 | 9 | 10 |
11 | 12 | 13 | 14 | 15 |
16 | 17 | 18 | 19 | 20 |
End |
Return
You have completed
questions
question
Your score is
Correct
Wrong
Partial-Credit
You have not finished your quiz. If you leave this page, your progress will be lost.
Correct Answer
You Selected
Not Attempted
Final Score on Quiz
Attempted Questions Correct
Attempted Questions Wrong
Questions Not Attempted
Total Questions on Quiz
Question Details
Results
Date
Score
Hint
Time allowed
minutes
seconds
Time used
Answer Choice(s) Selected
Question Text
All done
Need more practice!
Keep trying!
Not bad!
Good work!
Perfect!