Question 1 |
A strobe tachometer is used to measure?
A | Air speed |
B | Blower speed |
C | Air volume |
D | Static pressure
|
Question 2 |
A strobe tachometer’s measurements are read in ?
A | Fpm |
B | Rpm |
C | Cfm |
D | Inches W.C |
Question 3 |
A pitot-tube has the capability of measuring
A | Static pressure |
B | Velocity pressure |
C | Velocity and static pressure |
D | Cfm |
Question 4 |
The holes on the side of a pitot-tube are used to measure
A | Static pressure |
B | Velocity pressure |
C | Velocity and static pressure |
D | Total pressure |
Question 5 |
The hole in the end of the pitot-tube is used to measure
A | Static pressure |
B | Velocity pressure |
C | Velocity and static pressure |
D | Total pressure |
Question 6 |
The speed of air in a duct system is measured in
A | cfm - cubic feet per minute |
B | fpm - feet per minute |
C | gpm - gallons per minute |
D | cfh - cubic feet per hour
|
Question 7 |
A pitot-tube traverse is commonly used to
A | take an average air velocity pressure reading in an air distribution system for the calculation of air volume. |
B | Take an average static pressure reading in an air distribution system for the calculation of air velocity. |
C | Take an average air volume reading in an air distribution system for the calculation of air velocity |
D | None of the above
|
Question 8 |
A pitot-tube traverse
A | Must be taken in the main supply and return duct system only |
B | Must be taken in the individual branch runs only |
C | Must be taken in the main supply duct only |
D | Can be taken in the main supply, return, and individual branch runs |
Question 9 |
A velometer measures
A | The quantity of air in a duct system |
B | The speed of the air in a duct system or at a diffuser |
C | The static pressure of the duct system |
D | None of the above
|
Question 10 |
What instrument is commonly used with a velometer to measure the air velocity at a supply register?
A | A pitot-tube |
B | A diffuser probe |
C | An air scoop |
D | A static ring
|
Question 11 |
An anemometer measures
A | Static pressure |
B | Velocity in inches W.C. |
C | Velocity in feet per minute |
D | Quantity of air in cubic feet per minute
|
Question 12 |
What are two common types of anemometers used for airflow testing?
A | A vane type and a pitot type |
B | A hot wire and a vane type |
C | A hot wire type and a pitot tube |
D | None of the above |
Question 13 |
What is considered static pressure in a duct sytem?
A | The speed of the air in the duct system |
B | The pressure of the air flowing down the duct system |
C | The pressure of the air pushing in all direction in a duct system |
D | The total pressure in the duct system
|
Question 14 |
What instrument must be used with a manometer to measure static, velocity, and total pressure?
A | A pitot-tube |
B | An incline gauge |
C | An anemometer |
D | A static disc |
Question 15 |
Which of the following formulas is correct?
A | Static pressure/velocity pressure = total pressure |
B | Velocity pressure – static pressure = total pressure |
C | Velocity pressure X static pressure = total pressure |
D | Static pressure + velocity pressure = total pressure
|
Question 16 |
A U-tube manometer is commonly used to measure pressures
A | Below 1” WC |
B | Above 1” WC |
C | Up to 40” WC |
D | None of the above |
Question 17 |
An incline manometer is commonly used to measure pressures
A | Below 1” WC |
B | Above 1” WC |
C | Up to 40” WC |
D | None of the above
|
Question 18 |
What type of gauge uses a high and low pressure port to measure a pressure difference between two different pressure locations?
A | A high pressure gauge |
B | A low pressure gauge |
C | A differential pressure gauge |
D | A high/low pressure gauge
|
Question 19 |
Air volume is measure in
A | Cfm |
B | Fpm |
C | Inches WC |
D | Inches Hg |
Question 20 |
Which of the following formulas is correct
A | Area + velocity = cfm |
B | Velocity X area = cfm |
C | Velocity/area = cfm |
D | Area – velocity = cfm
|
Question 21 |
If an 8” X 22” supply air duct has air that is travelling at the speed of 1000 fpm. What is the quantity of the air moving through the system?
A | 176,000 cfm |
B | 1,760 cfm |
C | 1,222 cfm |
D | 122 cfm
|
Question 22 |
An 8” X 12" register has a velocity of 300 fpm with free area of 75% what is the quantity of air exiting the register?
A | 1,800 cfm |
B | 2,880 cfm |
C | 200 cfm |
D | 150 cfm
|
Question 23 |
An airhood is commonly used for measuring
A | cfm |
B | fpm |
C | Static pressure |
D | Velocity pressure
|
Question 24 |
Which of the following formulas is correct?
A | Cfm = input BTUH / 1.08 X temperature difference |
B | Cfm = output BTUH X 1.08 X temperature difference |
C | Cfm = input BTUH / 1.08 + temperature difference |
D | Cfm = output BTUH / 1.08 X temperature difference |
Question 25 |
If the temperature difference across a heat exchanger is 70 degrees and the output of a furnace is 82,000 BTUH what would be the cfm of the blower?
A | 950 cfm |
B | 1,045 cfm |
C | 1,085 cfm |
D | 1,125 cfm |
Question 26 |
At what speed does the blower have to be set for the temperature rise test?
A | Low |
B | Med |
C | High |
D | The heat cycle will set the speed |
Question 27 |
Return air temperature is 70 degrees, supply is 130. When clocking the gas meter it takes 100 seconds to cycle the 2 cu ft dial. What is my cfm?
A | 950cfm |
B | 1111 cfm |
C | 1500 cfm |
D | 1,125 cfm
|
Question 28 |
While testing the heat rise with electric heat, the following was recorded. Volts 228, Amps 27.6, temperature difference 26 degrees. What is the cfm?
A | 950 cfm |
B | 767 cfm |
C | 1111 cfm |
D | 1,125 cfm
|
Question 29 |
Calculate air volume based on these conditions: 90,000 BTUH output, return temperature 70 degrees, supply temperature 110.
A | 1158 cfm |
B | 1500 cfm |
C | 1800 cfm |
D | 2083 cfm |
Question 30 |
If a single phase electric heat section is supplied with 227 volts, 45 amps the BTUH output is?
A | 34,500 BTUH |
B | 25,000 BTUH |
C | 36,000 BTUH |
D | 42,000 BTUH |
Question 31 |
The pressure gauge used to sense external static pressure in a residential duct system should have a scale of
A | 0 - 1” WC |
B | 0 -2” WC |
C | 0 – 10” WC |
D | 0 – 40” WC |
Question 32 |
Taking average readings of air velocity in the cross sectional area of a duct is called
A | Surveying |
B | Traversing |
C | Averaging |
D | Estimating |
Question 33 |
If the velocity of air in a 20 X 10 duct is 750 fpm, what is the amount air being delivered by this duct?
A | 1209 cfm |
B | 904 cfm |
C | 1042 cfm |
D | 825 cfm
|
Question 34 |
If the velocity of air in a 20 X 10 duct is 650 fpm, what is the air being delivered by this duct?
A | 1209 cfm |
B | 904 cfm |
C | 1042 cfm |
D | 825 cfm |
Once you are finished, click the button below. Any items you have not completed will be marked incorrect.
Get Results
There are 34 questions to complete.
← |
List |
→ |
Return
Shaded items are complete.
1 | 2 | 3 | 4 | 5 |
6 | 7 | 8 | 9 | 10 |
11 | 12 | 13 | 14 | 15 |
16 | 17 | 18 | 19 | 20 |
21 | 22 | 23 | 24 | 25 |
26 | 27 | 28 | 29 | 30 |
31 | 32 | 33 | 34 | End |
Return
You have completed
questions
question
Your score is
Correct
Wrong
Partial-Credit
You have not finished your quiz. If you leave this page, your progress will be lost.
Correct Answer
You Selected
Not Attempted
Final Score on Quiz
Attempted Questions Correct
Attempted Questions Wrong
Questions Not Attempted
Total Questions on Quiz
Question Details
Results
Date
Score
Hint
Time allowed
minutes
seconds
Time used
Answer Choice(s) Selected
Question Text
All done
Need more practice!
Keep trying!
Not bad!
Good work!
Perfect!